Skip to content
CCNA 200-301 v1.1 reference — Network Fundamentals

Interface status and error troubleshooting

Read interface status codes and counters, and isolate collisions, CRC errors, duplex and speed mismatches, and cabling faults.

Objective 1.4v1.1 exam target

Reading interface status

Interface status combinations

Line protocolStatusMeaningFirst suspects
up / upWorkingL1 and L2 operationalLook elsewhere — issue is higher in the stack
up / downL2 problemPhysical link OK, protocol failingEncapsulation mismatch, keepalive issues
down / downL1 problemNo carrier detectedCable, optic, far-end shutdown, bad port
administratively down / downShutdownshutdown configuredSomeone disabled it — no shutdown
down / down (err-disabled)Disabled by featurePort security, BPDU guard, link-flap, etc.show interface status err-disabled for reason
$ show interfaces gi0/1
GigabitEthernet0/1 is up, line protocol is upL1 and L2 both operational.
Hardware is iGbE, address is 00aa.bb01.0201 (bia 00aa.bb01.0201)Burned-in vs configured MAC.
Full-duplex, 1000Mb/s, media type is 10/100/1000BaseTXNegotiated speed and duplex — compare both ends.
0 runts, 0 giants, 0 throttlesClean physical layer so far.
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignoredAny growth here points at media/duplex.
0 output errors, 0 collisions, 1 interface resetsCollisions should be zero on full-duplex.

Duplex mismatches and error counters

Duplex mismatch happens when one end runs full-duplex and the other half-duplex — usually because one side was hard-coded while the other still autonegotiates (autonegotiation then fails and falls back to half-duplex). The full-duplex side transmits whenever it likes; the half-duplex side treats those simultaneous transmissions as collisions and backs off, producing CRC errors, runts and late collisions and terrible throughput that still 'passes ping'. The fix is symmetric configuration: autonegotiation on both ends, or identical hard-coded speed/duplex on both ends.

Error counters and what they indicate

CounterMeaningLikely cause
CRC / FCS errorsFrame checksum failed on receiptPhysical-layer suspect — compare counter deltas over time with cable/optic condition
RuntsFrames shorter than 64 bytesCollisions (half-duplex), duplex mismatch, faulty NIC
GiantsFrames over the interface MTUMTU mismatch, baby giants/jumbo misconfig
CollisionsContention on shared mediaHalf-duplex link, duplex mismatch
Late collisionsCollision detected after 512 bitsDuplex mismatch is the classic cause
Input/output errorsGeneral receive/transmit failuresBuffer overruns, physical faults
Interpret conflicting symptoms
Symptom
Server link 'up/up' but backups crawl; collisions and late collisions increment
Config
Switch hard-coded 1000/full; NIC set to autonegotiate
  1. With switch autonegotiation disabled, the NIC cannot negotiate and falls back to half-duplex at 100 Mb while the switch stays hard-coded 100/full.
  2. The switch transmits full-duplex frames whenever queued; the NIC's half-duplex CSMA/CD logic calls them collisions.
  3. Result: link is up, pings pass, throughput collapses and late collisions accumulate — the classic signature.

Set the NIC to 1000/full explicitly (or re-enable autonegotiation on the switch) so both ends agree.

Verification workflow

Interface health check

Baseline interface state and error counters — Privileged EXEC

Cisco IOS / IOS XE

Verify
show ip interface brief
show interfaces status
show interfaces gi0/1
show interfaces gi0/1 counters errors
  • show ip interface brief reveals status/protocol pairs at a glance.
  • show interfaces status exposes negotiated speed/duplex and err-disabled.
  • Error counters near zero and non-incrementing indicate a healthy physical link.
  • Counter snapshots are meaningless alone — clear and re-check to see increments.

Read-only verification commands.

Common mistakes

  • Declaring 'cable fault' on an up/down status — up/down means L1 is fine; look at L2 causes first.
  • Reading one snapshot of error counters — only increments over time are diagnostic.
  • Hard-coding speed/duplex on one end only — the autonegotiating side can fall back to half-duplex, creating a mismatch.
  • Expecting collisions on a healthy full-duplex link — any late collisions are abnormal.
  • Treating err-disabled as a hardware failure — it is a feature action; find and fix the trigger first.
Intermittent connectivity on an access port

Observation: Users report brief drops; interface shows up/up with incrementing CRC errors.

Hypotheses
  • Damaged cable or connector
  • Duplex mismatch
  • Failing NIC or transceiver
CheckIndicates
show interfaces over timeGrowing CRC with clean duplex counters points at media, not negotiation.
show interfaces status speed/duplex vs far endMismatched duplex explains collisions; CRC alone favors a physical fault.
Swap patch lead / move to a known-good portFault following the cable or the port localizes the component.

Correction: Replace the faulty media or set matching speed/duplex on both ends.

Counters stay flat and user drops stop; no new CRC increments after a busy period.

On this page

Related resources

Sources

Targets CCNA 200-301 v1.1 objectives. Supplemental blocks are labeled beyond exam scope.