Cabling and media

Copper UTP categories, single-mode versus multimode fiber, Ethernet shared media and point-to-point connections, and Power over Ethernet.

Objective 1.3v1.1 exam target

Copper and fiber media

Copper UTP dominates horizontal access runs. Higher categories tighten twist rates and shielding to support higher frequencies: Cat5e and Cat6 carry 1G to 100 m; Cat6a carries 10G to 100 m. Copper is cheap and carries PoE, but it suffers EMI pickup and the hard 100 m channel limit (90 m permanent link + 10 m patch).

Single-mode versus multimode fiber

Fiber is immune to EMI and beats the 100 m copper limit; pick SMF for distance and future speed.
PropertyMultimode (MMF)Single-mode (SMF)
Core diameter50 µm (OM3/OM4) or 62.5 µm (OM1)~9 µm
Light sourceLED/VCSEL, 850 nmLaser, 1310/1550 nm
Modal dispersionLimits reachNegligible — one light path
Typical reach (10G)300 m (OM3) / 400 m (OM4)10 km+ (10GBASE-LR)
Relative costCheaper opticsCheaper per metre cable, pricier optics
UseInside buildings/data hallsBetween buildings, campus backbone, WAN

Fiber is immune to EMI and beats the 100 m copper limit; pick SMF for distance and future speed.

Copper UTP categories (100 m channel)

CategoryRatingNotes
Cat5e1000BASE-TBaseline for gigabit access runs
Cat61G, 10G to ~55 mBetter crosstalk margin than Cat5e
Cat6a10GBASE-T to 100 mThicker, often shielded

Shared media and point-to-point

Ethernet links are either point-to-point or shared media. A full-duplex link between a host and a switch port is point-to-point: only two transmitters exist, so collisions are impossible and both ends can send simultaneously. Legacy hubs create a shared media half-duplex segment where CSMA/CD arbitrates — one transmitter at a time, collisions normal. Modern switched networks are effectively all point-to-point full-duplex; a half-duplex reading on a switchport today is a fault indicator, not a design.

Pick the media for an inter-building link
Distance
450 m between buildings
Speed
10 Gbps required
Environment
Heavy electrical equipment nearby
  1. Copper fails immediately: the 100 m channel limit cannot reach 450 m.
  2. MMF OM3 only reaches ~300 m at 10G — marginal for the distance (both fiber types ignore EMI).
  3. SMF with 10GBASE-LR optics reaches ~10 km comfortably.

Single-mode fiber with LR optics is the only listed option that meets the 1 km distance at 10G.

Verification and troubleshooting

Verifying the physical layer

  • show interfaces status shows speed, duplex and whether the link trained at the expected rate.
  • An interface stuck at 100 Mb on a known-gigabit cable run suggests a bad pair or damaged termination — gigabit needs all four pairs.
  • show interfaces counters such as CRC and runts point to physical-layer faults; verify media before blaming configuration.
  • Fiber links that pass light but flap can indicate dirty connectors or the wrong optic type for the cable plant.

Common mistakes

  • Assuming 'fiber is always faster' — optics and standard determine speed; MMF and SMF carry the same rates at different distances.
  • Running 10G over Cat6 for the full 100 m — Cat6 10G reach is roughly 55 m; use Cat6a or fiber.
  • Ignoring that gigabit copper needs all four pairs working — a single bad pair falls back to 100 Mb on many NICs.
  • Using a crossover cable mindset on modern gear — Auto-MDIX makes straight cables work in most cases.
Link trains at 100 Mb instead of 1000 Mb

Observation: A Cat6 run negotiates 100 Mbps on both ends.

Hypotheses
  • One or more of the four pairs damaged or mis-terminated
  • Keystone/patch panel rated below the cable category
  • Hard-set speed/duplex on one end
CheckIndicates
show interfaces statusConfirms the negotiated rate and duplex actually in use.
Cable tester on all four pairsA failed pair directly explains the 100M fallback.
show running-config interfaceA hard-coded speed 100 overrides autonegotiation.

Correction: Re-terminate or replace the faulty run/component; restore autonegotiation or matching hard settings on both ends.

Interface trains at 1000/full and error counters stop incrementing.